Description
SRC10KUXI Key Features
Main |
|
acoustic level |
58 dBA |
battery curve |
B |
battery type |
External battery system |
bypass type |
Built-in static bypass |
crest factor |
3:01 |
curve equation |
Efficiency |
curve load maximum |
100 % |
curve X-axis maximum |
100 % |
curve X-axis minimum |
0 % |
curve X-axis title |
Load |
curve X-axis units |
Percentage |
curve Y-axis maximum |
100 % |
curve Y-axis minimum |
50 % |
curve Y-axis title |
Efficiency |
curve Y-axis units |
Percentage |
Emergency power off |
Yes |
extended runtime |
0 |
Maximum configurable power in VA |
10000 VA |
Maximum configurable power in W |
9000 W |
liquid value |
0 |
load power factor |
0.5 leading to 0.5 lagging |
mounting mode |
Not rack-mountable |
mounting preference |
No preference |
number of battery filled slots |
0 |
number of battery free slots |
0 |
Battery recharge time |
5 h |
cos phi |
0.98 |
depth |
70.6 cm |
free slots |
1 |
height |
43.3 cm |
Number of power module filled slots |
0 |
Number of power module free slots |
0 |
net weight |
27.5 kg |
rated power in VA |
10000 VA |
rated power in W |
9000 W |
Number of tare power |
525 W |
width |
13.4 cm |
operating altitude |
0…10000 ft |
output harmonic distortion |
< 2% for 0 to 100% linear load and < 5% for full non-linear load |
output overload operation |
60 seconds at 125% and 30 seconds at 150% |
output voltage tolerance |
+/- 1% static and +/- 5% at 100% load step |
ambient air temperature for operation |
0…40 °C |
ambient air temperature for storage |
-10…60 °C |
storage altitude |
0.00…15240.00 m |
UPS size |
S |
UPS type |
Double conversion online |
Wave type |
Sine wave |
graph display |
1 |
redundant |
No |
show note OP temperature |
No |
two post mountable |
0 |
No |
|
number of input connectors |
1 hard wire 3-wire (1P + N + E) |
1 hard wire 5-wire (3P + N + E) |
|
input voltage |
230 V |
input voltage limits |
100…280 V adjustable |
160…285 V |
|
IP degree of protection |
IP20 |
efficiency |
94.4 % (full load) |
94.5 % (half load) |
|
network frequency |
40…70 Hz auto-sensing |
output connector type |
Hard wire 3-wire (H N + E) 1 |
output voltage |
230 V |
provided equipment |
Basic UPS signalling RS-232 cable |
Dust filter |
|
User manual |
|
Warranty card |
|
relative humidity |
0…95 % non-condensing |
battery option |
SRC192XLBP-IN 1 1958 VAh |
SRC192XLBP-IN 2 3916 VAh |
|
SRC192XLBP-IN 3 5874 VAh |
|
SRC192XLBP-IN 4 7832 VAh |
|
Battery power in VAH |
0 VAh runtime |
input current |
81 A (1 phase) |
28 A per phase (3 phases) |
|
outputvolt_other |
220 V |
240 V |
|
harmonic distortion |
Less than 2 % |
Output |
|
output frequency |
47…53 Hz for 50 Hz nominal sync to mains |
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
|
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
|
50/60 Hz +/- 1 Hz sync to mains |
|
50/60 Hz +/- 3 Hz sync to mains |
|
Packing Units |
|
Package 1 Weight |
32 kg |
Package 1 Height |
57 cm |
Package 1 width |
27.5 cm |
Package 1 Length |
79 cm |
Offer Sustainability |
|
EU RoHS Directive |
Compliant |
EU RoHS Declaration |
|
Mercury free |
Yes |
RoHS exemption information |
Yes |
Contractual warranty |
|
Warranty |
2 years repair or replace |
Reviews