TeSys D contactor – 3P 3 NO – AC-3 – <= 440 V 12 A - 110 V AC coil LC1D12F7

TeSys D contactor – 3P 3 NO – AC-3 – <= 440 V 12 A - 110 V AC coil LC1D12F7

SKU: LC1D12F7 Category: Tag:

Compare

Description

LC1D12F7 – specification

Main

range

TeSys

product name

TeSys D

product or component type

Contactor

device short name

LC1D

contactor application

Resistive load

Motor control

utilisation category

AC-3

AC-4

AC-1

poles description

3P

power pole contact composition

3 NO

[Ue] rated operational voltage

Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current

25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

motor power kW

3 kW at 220…230 V AC 50/60 Hz (AC-3)

5.5 kW at 380…400 V AC 50/60 Hz (AC-3)

5.5 kW at 415…440 V AC 50/60 Hz (AC-3)

7.5 kW at 500 V AC 50/60 Hz (AC-3)

7.5 kW at 660…690 V AC 50/60 Hz (AC-3)

3.7 kW at 400 V AC 50/60 Hz (AC-4)

motor power HP (UL / CSA)

0.5 hp at 115 V AC 50/60 Hz for 1 phase motors

2 hp at 230/240 V AC 50/60 Hz for 1 phase motors

3 hp at 200/208 V AC 50/60 Hz for 3 phases motors

3 hp at 230/240 V AC 50/60 Hz for 3 phases motors

7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors

10 hp at 575/600 V AC 50/60 Hz for 3 phases motors

control circuit type

AC at 50/60 Hz

[Uc] control circuit voltage

110 V AC 50/60 Hz

auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

overvoltage category

III

[Ith] conventional free air thermal current

25 A (at 60 °C) for power circuit

10 A (at 60 °C) for signalling circuit

Irms rated making capacity

250 A at 440 V for power circuit conforming to IEC 60947

140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

rated breaking capacity

250 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

105 A 40 °C – 10 s for power circuit

210 A 40 °C – 1 s for power circuit

30 A 40 °C – 10 min for power circuit

61 A 40 °C – 1 min for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1

40 A gG at <= 690 V coordination type 1 for power circuit

25 A gG at <= 690 V coordination type 2 for power circuit

average impedance

2.5 mOhm – Ith 25 A 50 Hz for power circuit

[Ui] rated insulation voltage

Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

electrical durability

2 Mcycles 12 A AC-3 at Ue <= 440 V

0.8 Mcycles 25 A AC-1 at Ue <= 440 V

power dissipation per pole

0.36 W AC-3

1.56 W AC-1

Front cover

With

mounting support

Rail

Plate

standards

CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

product certifications

CCC

BV

CSA

GL

UL

RINA

GOST

LROS (Lloyds register of shipping)

DNV

connections – terminals

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end

tightening torque

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

operating time

12…22 ms closing

4…19 ms opening

safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

mechanical durability

15 Mcycles

maximum operating rate

3600 cyc/h 60 °C

Complementary

coil technology

Without built-in suppressor module

inrush power in VA

70 VA 60 Hz cos phi 0.75 (at 20 °C)

70 VA 50 Hz cos phi 0.75 (at 20 °C)

hold-in power consumption in VA

7.5 VA 60 Hz cos phi 0.3 (at 20 °C)

7 VA 50 Hz cos phi 0.3 (at 20 °C)

heat dissipation

2…3 W at 50/60 Hz

auxiliary contacts type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1

type mirror contact 1 NC conforming to IEC 60947-4-1

signalling circuit frequency

25…400 Hz

minimum switching current

5 mA for signalling circuit

minimum switching voltage

17 V for signalling circuit

non-overlap time

1.5 ms on de-energisation between NC and NO contact

1.5 ms on energisation between NC and NO contact

insulation resistance

> 10 MOhm for signalling circuit

contact compatibility

M2

compatibility code

LC1D

motor power range

4…6 kW at 380…440 V 3 phases

4…6 kW at 480…500 V 3 phases

2.2…3 kW at 200…240 V 3 phases

motor starter type

Direct on-line contactor

contactor coil voltage

110 V AC standard

Environment

IP degree of protection

IP20 front face conforming to IEC 60529

protective treatment

TH conforming to IEC 60068-2-30

pollution degree

3

ambient air temperature for storage

-60…80 °C

operating altitude

3000 m without derating

fire resistance

850 °C conforming to IEC 60695-2-1

flame retardance

V1 conforming to UL 94

mechanical robustness

Vibrations contactor open: 2 Gn, 5…300 Hz

Vibrations contactor closed: 4 Gn, 5…300 Hz

Shocks contactor open: 10 Gn for 11 ms

Shocks contactor closed: 15 Gn for 11 ms

height

77 mm

width

45 mm

depth

86 mm

net weight

0.325 kg

Packing Units

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

356 g

Package 1 Height

5 cm

Package 1 width

9.2 cm

Package 1 Length

11.2 cm

Unit Type of Package 2

S02

Number of Units in Package 2

20

Package 2 Weight

7.411 kg

Package 2 Height

15 cm

Package 2 width

30 cm

Package 2 Length

40 cm

Unit Type of Package 3

P06

Number of Units in Package 3

320

Package 3 Weight

129.38 kg

Package 3 Height

80 cm

Package 3 width

80 cm

Package 3 Length

60 cm

Offer Sustainability

Sustainable offer status

Green Premium product

REACh free of SVHC

Yes

EU RoHS Directive

Compliant

EU RoHS Declaration

Toxic heavy metal free

Yes

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

PVC free

Yes

Contractual warranty

Warranty

18 months

Reviews

There are no reviews yet.

Be the first to review “TeSys D contactor – 3P 3 NO – AC-3 – <= 440 V 12 A - 110 V AC coil LC1D12F7”

Your email address will not be published. Required fields are marked *