TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 150 A - 110 V AC 50/60 Hz coil LC1D150F7

TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 150 A - 110 V AC 50/60 Hz coil LC1D150F7

SKU: LC1D150F7 Category: Tag:

Compare

Description

Main

range

TeSys

product name

TeSys D

product or component type

Contactor

device short name

LC1D

contactor application

Motor control
Resistive load

utilisation category

AC-4
AC-3
AC-1

poles description

3P

power pole contact composition

3 NO

[Ue] rated operational voltage

Power circuit <= 1000 V AC 25…400 Hz
Power circuit <= 300 V DC

[Ie] rated operational current

200 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
150 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit

motor power kW

40 kW 220…230 V AC 50/60 Hz AC-3)
75 kW 380…400 V AC 50/60 Hz AC-3)
80 kW 415…440 V AC 50/60 Hz AC-3)
90 kW 500 V AC 50/60 Hz AC-3)
100 kW 660…690 V AC 50/60 Hz AC-3)
75 kW 1000 V AC 50/60 Hz AC-3)
22 kW 400 V AC 50/60 Hz AC-4)

motor power HP (UL / CSA)

40 hp 200/208 V AC 50/60 Hz 3 phases
50 hp 230/240 V AC 50/60 Hz 3 phases
100 hp 460/480 V AC 50/60 Hz 3 phases
125 hp 575/600 V AC 50/60 Hz 3 phases

control circuit type

AC 50/60 Hz

[Uc] control circuit voltage

110 V AC 50/60 Hz

auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

8 kV IEC 60947

overvoltage category

III

[Ith] conventional free air thermal current

200 A 140 °F (60 °C) power circuit

Irms rated making capacity

140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
1660 A 440 V power circuit IEC 60947

rated breaking capacity

1400 A 440 V power circuit IEC 60947

[Icw] rated short-time withstand current

250 A 104 °F (40 °C) – 10 min power circuit
580 A 104 °F (40 °C) – 1 min power circuit
1200 A 104 °F (40 °C) – 10 s power circuit
1400 A 104 °F (40 °C) – 1 s power circuit
100 A – 1 s signalling circuit
120 A – 500 ms signalling circuit
140 A – 100 ms signalling circuit

associated fuse rating

10 A gG signalling circuit IEC 60947-5-1
315 A gG <= 690 V type 1 power circuit
250 A gG <= 690 V type 2 power circuit

average impedance

0.6 mOhm – Ith 200 A 50 Hz power circuit

[Ui] rated insulation voltage

Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL

electrical durability

0.85 Mcycles 150 A AC-3 <= 440 V
1 Mcycles 200 A AC-1 <= 440 V

power dissipation per pole

24 W AC-1
13.5 W AC-3

safety cover

With

mounting support

Plate
Rail

standards

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508

product certifications

CCC
GOST
DNV
UL
LROS (Lloyds register of shipping)
BV
GL
RINA
CSA

connections – terminals

Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)solid without cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible without cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible without cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)flexible with cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)flexible with cable end
Power circuit connector 1 0.02…0.19 in² (10…120 mm²)solid without cable end
Power circuit connector 2 0.02…0.08 in² (10…50 mm²)solid without cable end

tightening torque

Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm)

operating time

20…35 ms closing
40…75 ms opening

safety reliability level

B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

mechanical durability

8 Mcycles

maximum operating rate

1200 cyc/h 140 °F (60 °C)

Complementary

coil technology

Built-in bidirectional peak limiting diode suppressor

control circuit voltage limits

Drop-out 0.3…0.5 Uc AC 50/60 Hz 131 °F (55 °C))
Operational 0.8…1.15 Uc AC 50/60 Hz 131 °F (55 °C))

inrush power in VA

280…350 VA 60 Hz 0.9 68 °F (20 °C))
280…350 VA 50 Hz 0.9 68 °F (20 °C))

hold-in power consumption in VA

2…18 VA 60 Hz 0.9 68 °F (20 °C))
2…18 VA 50 Hz 0.9 68 °F (20 °C))

heat dissipation

3…4.5 W 50/60 Hz

auxiliary contacts type

Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1

signalling circuit frequency

25…400 Hz

minimum switching current

5 mA signalling circuit

minimum switching voltage

17 V signalling circuit

non-overlap time

1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact

insulation resistance

> 10 MOhm signalling circuit

Environment

IP degree of protection

IP20 front face IEC 60529

protective treatment

TH IEC 60068-2-30

pollution degree

3

ambient air temperature for operation

23…140 °F (-5…60 °C)

ambient air temperature for storage

-76…176 °F (-60…80 °C)

permissible ambient air temperature around the device

-40…158 °F (-40…70 °C) at Uc

operating altitude

9842.52 ft (3000 m) without

fire resistance

1562 °F (850 °C) IEC 60695-2-1

flame retardance

V1 UL 94

mechanical robustness

Vibrations contactor open2 Gn, 5…300 Hz
Vibrations contactor closed4 Gn, 5…300 Hz
Shocks contactor closed15 Gn for 11 ms
Shocks contactor open6 Gn for 11 ms

height

6.22 in (158 mm)

width

4.72 in (120 mm)

depth

5.35 in (136 mm)

net weight

5.51 lb(US) (2.5 kg)

Ordering and shipping details

Category

22359 – CTR,TESYS D,OPEN,80-150A AC&DC

Discount Schedule

I12

GTIN

00785901214489

Package weight(Lbs)

2.47 kg (5.44 lb(US))

Returnability

Yes

Country of origin

CZ

Offer Sustainability

Sustainable offer status

Green Premium product

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov

REACh Regulation

REACh Declaration

EU RoHS Directive

Compliant
EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration
Product out of China RoHS scope. Substance declaration for your information.

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Contractual warranty

Warranty

18 months

Reviews

There are no reviews yet.

Be the first to review “TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 150 A - 110 V AC 50/60 Hz coil LC1D150F7”

Your email address will not be published. Required fields are marked *