TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A - 24 V DC coil LC1D18BD

TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A - 24 V DC coil LC1D18BD

SKU: LC1D18BD Category: Tag:

Compare

Description

Main

range

TeSys

product name

TeSys D

product or component type

Contactor

device short name

LC1D

contactor application

Motor control

Resistive load

utilisation category

AC-4

AC-1

AC-3

poles description

3P

power pole contact composition

3 NO

[Ue] rated operational voltage

Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

[Ie] rated operational current

18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

motor power kW

4 kW at 220…230 V AC 50/60 Hz (AC-3)

7.5 kW at 380…400 V AC 50/60 Hz (AC-3)

9 kW at 415…440 V AC 50/60 Hz (AC-3)

10 kW at 500 V AC 50/60 Hz (AC-3)

10 kW at 660…690 V AC 50/60 Hz (AC-3)

4 kW at 400 V AC 50/60 Hz (AC-4)

motor power HP (UL / CSA)

1 hp at 115 V AC 50/60 Hz for 1 phase motors

3 hp at 230/240 V AC 50/60 Hz for 1 phase motors

5 hp at 200/208 V AC 50/60 Hz for 3 phases motors

5 hp at 230/240 V AC 50/60 Hz for 3 phases motors

10 hp at 460/480 V AC 50/60 Hz for 3 phases motors

15 hp at 575/600 V AC 50/60 Hz for 3 phases motors

control circuit type

DC standard

[Uc] control circuit voltage

24 V DC

auxiliary contact composition

1 NO + 1 NC

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

overvoltage category

III

[Ith] conventional free air thermal current

10 A (at 60 °C) for signalling circuit

32 A (at 60 °C) for power circuit

Irms rated making capacity

140 A AC for signalling circuit conforming to IEC 60947-5-1

250 A DC for signalling circuit conforming to IEC 60947-5-1

300 A at 440 V for power circuit conforming to IEC 60947

rated breaking capacity

300 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand current

145 A 40 °C – 10 s for power circuit

240 A 40 °C – 1 s for power circuit

40 A 40 °C – 10 min for power circuit

84 A 40 °C – 1 min for power circuit

100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit

140 A – 100 ms for signalling circuit

associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1

50 A gG at <= 690 V coordination type 1 for power circuit

35 A gG at <= 690 V coordination type 2 for power circuit

average impedance

2.5 mOhm – Ith 32 A 50 Hz for power circuit

[Ui] rated insulation voltage

Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified

Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1

Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

electrical durability

1.65 Mcycles 18 A AC-3 at Ue <= 440 V

1 Mcycles 32 A AC-1 at Ue <= 440 V

power dissipation per pole

2.5 W AC-1

0.8 W AC-3

safety cover

With

mounting support

Plate

Rail

standards

CSA C22.2 No 14

EN 60947-4-1

EN 60947-5-1

IEC 60947-4-1

IEC 60947-5-1

UL 508

product certifications

LROS (Lloyds register of shipping)

DNV

GL

RINA

BV

CCC

UL

CSA

GOST

connections – terminals

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end

Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²flexible without cable end

Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²flexible without cable end

Power circuit: screw clamp terminals 1 cable(s) 1…6 mm²flexible with cable end

Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end

Power circuit: screw clamp terminals 1 cable(s) 1.5…6 mm²solid without cable end

Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm²solid without cable end

tightening torque

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm

Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2

operating time

53.55…72.45 ms closing

16…24 ms opening

safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

mechanical durability

30 Mcycles

maximum operating rate

3600 cyc/h 60 °C

Complementary

coil technology

With integral suppression device

control circuit voltage limits

Drop-out: 0.1…0.25 Uc DC (at 60 °C)

Operational: 0.7…1.25 Uc DC (at 60 °C)

time constant

28 ms

inrush power in W

5.4 W (at 20 °C)

hold-in power consumption in W

5.4 W at 20 °C

auxiliary contacts type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1

type mirror contact 1 NC conforming to IEC 60947-4-1

signalling circuit frequency

25…400 Hz

minimum switching current

5 mA for signalling circuit

minimum switching voltage

17 V for signalling circuit

non-overlap time

1.5 ms on de-energisation between NC and NO contact

1.5 ms on energisation between NC and NO contact

insulation resistance

> 10 MOhm for signalling circuit

Environment

IP degree of protection

IP20 front face conforming to IEC 60529

protective treatment

TH conforming to IEC 60068-2-30

pollution degree

3

ambient air temperature for operation

-5…60 °C

ambient air temperature for storage

-60…80 °C

permissible ambient air temperature around the device

-40…70 °C at Uc

operating altitude

3000 m without

fire resistance

850 °C conforming to IEC 60695-2-1

flame retardance

V1 conforming to UL 94

mechanical robustness

Vibrations contactor open: 2 Gn, 5…300 Hz

Vibrations contactor closed: 4 Gn, 5…300 Hz

Shocks contactor open: 10 Gn for 11 ms

Shocks contactor closed: 15 Gn for 11 ms

height

77 mm

width

45 mm

depth

95 mm

net weight

0.49 kg

Offer Sustainability

Sustainable offer status

Green Premium product

REACh Regulation

REACh Declaration

EU RoHS Directive

Compliant

EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Contractual warranty

Warranty

18 months