Description
BE800-IND Features
acoustic level | 45 dBA |
battery curve | A |
battery type | Lead-acid battery |
product certifications | BIS |
curve equation | Efficiency |
curve load maximum | 100 % |
curve X-axis maximum | 100 % |
curve X-axis minimum | 0 % |
curve X-axis title | Load |
curve X-axis units | Percentage |
curve Y-axis maximum | 100 % |
curve Y-axis minimum | 50 % |
curve Y-axis title | Efficiency |
curve Y-axis units | Percentage |
extended runtime | 0 |
Maximum configurable power in VA | 800 VA |
Maximum configurable power in W | 480 W |
liquid value | 0 |
mounting mode | Not rack-mountable |
mounting preference | No preference |
number of battery filled slots | 0 |
number of battery free slots | 0 |
Battery recharge time | 8 h |
depth | 29 cm |
height | 13 cm |
number of cables | 1 |
Number of power module filled slots | 0 |
Number of power module free slots | 0 |
net weight | 9 kg |
rated power in VA | 800 VA |
rated power in W | 480 W |
Surge energy rate | 160 J |
Number of tare power | 30 W |
width | 22 cm |
noise suppression | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
operating altitude | 0…10000 ft |
ambient air temperature for operation | 0…40 °C |
battery life | 2…4 year(s) |
ambient air temperature for storage | 0…45 °C |
storage altitude | 0.00…9144.00 m |
UPS size | WS |
UPS type | Line interactive |
Wave type | Stepped approximation to a sinewave |
graph display | 1 |
redundant | No |
show note OP temperature | No |
two post mountable | 0 |
No | |
input voltage | 230 V |
battery charger power | 17 W rated |
efficiency | 95 % (full load) |
nb of power socket outlets | 3 India 3-pin 6A |
1 India 3-pin 6A surge | |
network frequency | 50 Hz +/- 3 Hz |
output voltage | 230 V |
provided equipment | Installation guide |
User manual | |
Warranty card | |
relative humidity | 0…95 % |
Battery power in VAH | 135 VAh runtime |
Environment | |
heat dissipation | 42.68 Btu/h |
Input | |
plug standard | India 3-pin 6A |
Output | |
output frequency | 47…63 Hz sync to mains |
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised | |
Communications & Management | |
control panel | LED status display with on line : on battery : replace battery and building wiring fault |
alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Packing Units | |
Package 1 Weight | 10 kg |
Package 1 Height | 17 cm |
Package 1 width | 27 cm |
Package 1 Length | 41 cm |
Offer Sustainability | |
Sustainable offer status | Green Premium product |
REACh free of SVHC | Yes |
EU RoHS Directive | Compliant |
EU RoHS Declaration | |
Mercury free | Yes |
RoHS exemption information | Yes |
Contractual warranty | |
Warranty | 2 years repair or replace |
Reviews
There are no reviews yet.