Schneider TeSys F contactor – 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC LC1F630

Schneider TeSys F contactor – 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC LC1F630

Compare

Description

LC1F630 Specifications

Main

range

TeSys

product name

TeSys F

product or component type

Contactor

device short name

LC1F

contactor application

Resistive load

Motor control

utilisation category

AC-4

AC-1

AC-3

poles description

3P

power pole contact composition

3 NO

[Ue] rated operational voltage

<= 1000 V AC 50/60 Hz

<= 460 V DC

[Ie] rated operational current

1000 A (at <40 °C) at <= 440 V AC AC-1

630 A (at <55 °C) at <= 440 V AC AC-3

motor power kW

335 kW at 380…400 V AC 50/60 Hz (AC-3)

375 kW at 415 V AC 50/60 Hz (AC-3)

400 kW at 440 V AC 50/60 Hz (AC-3)

400 kW at 500 V AC 50/60 Hz (AC-3)

450 kW at 1000 V AC 50/60 Hz (AC-3)

200 kW at 220…240 V AC 50/60 Hz (AC-3)

450 kW at 660…690 V AC 50/60 Hz (AC-3)

100 kW at 400 V AC 50/60 Hz (AC-4)

Complementary

[Uc] control circuit voltage

48…1000 V AC 40…400 Hz with LX1/LX9 coil

48…440 V DC with LX4 coil

[Uimp] rated impulse withstand voltage

8 kV

overvoltage category

III

[Ith] conventional free air thermal current

1000 A (at 40 °C)

1250 A

Irms rated making capacity

6300 A AC conforming to IEC 60947-4-1

rated breaking capacity

5040 A conforming to IEC 60947-4-1

[Icw] rated short-time withstand current

5050 A 40 °C – 10 s

4400 A 40 °C – 30 s

3400 A 40 °C – 1 min

2200 A 40 °C – 3 min

1600 A 40 °C – 10 min

associated fuse rating

630 A aM at <= 440 V

1000 A gG at <= 440 V

average impedance

0.12 mOhm – Ith 1000 A 50 Hz

[Ui] rated insulation voltage

1000 V conforming to IEC 60947-4-1

1500 V conforming to VDE 0110 group C

power dissipation per pole

120 W AC-1

48 W AC-3

control circuit voltage limits

Operational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil

Drop-out: 0.25…0.5 Uc AC 40…400 Hz with LX1/LX9 coil

Operational: 0.85…1.1 Uc DC with LX4 coil

Drop-out: 0.2…0.35 Uc DC with LX4 coil

heat dissipation

20 W

operating time

40…80 ms closing for with LX1/LX9 coil

100…200 ms opening for with LX1/LX9 coil

60…70 ms closing for with LX4 coil

40…50 ms opening for with LX4 coil

mounting support

Plate

standards

EN 60947-4-1

IEC 60947-4-1

IEC 60947-1

JIS C8201-4-1

EN 60947-1

product certifications

ABS

UL

RINA

DNV

CSA

CB

LROS (Lloyds register of shipping)

BV

RMRoS

connections – terminals

Power circuit: bar 2 cable(s) – busbar cross section: 60 x 5 mm

Power circuit: bolted connection

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end

Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end

Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²

Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²

tightening torque

Power circuit: 58 N.m

Control circuit: 1.2 N.m

mechanical durability

5 Mcycles

inrush power in VA

1500…1730 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil

1420…1920 VA (at 20 °C)with LX4 coil

hold-in power consumption in VA

20…25 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil

6.5…12.5 VA (at 20 °C)with LX4 coil

maximum operating rate

1200 cyc/h 55 °C

compatibility code

LC1F

Environment

IP degree of protection

IP20 front face with shrouds conforming to IEC 60529

IP20 front face with shrouds conforming to VDE 0106

protective treatment

TH

ambient air temperature for operation

-5…55 °C

ambient air temperature for storage

-60…80 °C

permissible ambient air temperature around the device

-40…70 °C

operating altitude

3000 m without derating

mechanical robustness

Vibrations contactor open: 2 Gn, 5…300 Hz

Vibrations contactor closed: 4 Gn, 5…300 Hz

Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)

Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)

height

304 mm

width

309 mm

depth

255 mm

net weight

18.6 kg

Packing Units

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

17.11 kg

Package 1 Height

34 cm

Package 1 width

34 cm

Package 1 Length

45 cm

Unit Type of Package 2

P06

Number of Units in Package 2

4

Package 2 Weight

76.94 kg

Package 2 Height

80 cm

Package 2 width

80 cm

Package 2 Length

60 cm

Offer Sustainability

Sustainable offer status

Green Premium product

REACh Regulation

REACh Declaration

EU RoHS Directive

CompliantEU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declarationProduct out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Contractual warranty

Warranty

18 months

Reviews

There are no reviews yet.

Be the first to review “Schneider TeSys F contactor – 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC LC1F630”