Schneider Circuit breaker EasyPact CVS160F, 36 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d LV516332

Schneider Circuit breaker EasyPact CVS160F, 36 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d LV516332

SKU: LV516332 Category: Tag:

Compare

Description

LV516332 – specification

Main

range of product

Easypact CVS100…250

product or component type

Circuit breaker

device short name

CVS160F

device application

Distribution

poles description

3P

protected poles description

3d

Earth leakage protection (Vigi add on)

Without

[In] rated current

160 A at 40 °C

breaking capacity code

F

network type

AC

[Icu] Breaking capacity

36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2

36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

utilisation category

Category A

trip unit name

TM-D

trip unit technology

Thermal-magnetic

trip unit rating

125 A at 40 °C

protection type

Overload protection (thermal)

Short-circuit protection (magnetic)

Complementary

network frequency

50/60 Hz

control type

Toggle

mounting mode

Fixed

mounting support

Backplate

upside connection

Front

downside connection

Front

connections – terminals

Screw connection

[Uimp] rated impulse withstand voltage

8 kV conforming to EN/IEC 60947-2

thermal protection adjustment range

87.5…125 A

[Ics] rated service breaking capacity

18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2

36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2

70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2

mechanical durability

25000 cycles

electrical durability

12000 cycles 415 V In conforming to IEC 60947-2

connection pitch

35 mm

contact position indicator

Yes

long time pick-up adjustment type Ir

Adjustable

long time pick-up adjustment range

0.7…1 x In

long time delay adjustment type

Fixed

instantaneous pick-up adjustment type Ii

Fixed

instantaneous pick-up adjustment range

1250 A

height

161 mm

width

105 mm

depth

86 mm

net weight

1.8 kg

Environment

electrical shock protection class

Class II

standards

EN 60947-2

IEC 60947-2

product certifications

GOST

IEC

IP degree of protection

IP40

pollution degree

3 conforming to IEC 60664-1

ambient air temperature for operation

-25…70 °C

ambient air temperature for storage

-50…85 °C

Packing Units

Package 1 Weight

1.778 kg

Package 1 Height

15.800 cm

Package 1 width

9.000 cm

Package 1 Length

10.200 cm

Offer Sustainability

Sustainable offer status

Green Premium product

EU RoHS Directive

Compliant

EU RoHS Declaration

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Product out of China RoHS scope. Substance declaration for your information

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

WEEE

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Contractual warranty

Warranty

18 months

Reviews

There are no reviews yet.

Be the first to review “Schneider Circuit breaker EasyPact CVS160F, 36 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d LV516332”

Your email address will not be published. Required fields are marked *